title: '{{ document_title }}'
|
||
author: '{{ author_name }}'
|
||
date: \today{}
|
||
mainfont: DejaVu Sans
|
||
documentclass: article
|
||
fontsize: 12pt
|
||
# NOTE: The applegreen is a custom color defined in resources/head.tex
|
||
linkcolor: applegreen
|
||
urlcolor: applegreen
|
||
abstract: |
|
||
**Prepared For:**
|
||
|
||
{{ customer.name }}
|
||
|
||
{{ customer.address.street }}
|
||
{{ customer.address.city }}, {{ customer.address.state }} {{ customer.address.zip }}
|
||
|
||
```{=latex}
|
||
\begin{center}
|
||
```
|
||
<!-- below are just forced line breaks -->
|
||
\
|
||
\
|
||
\
|
||
|
||
[{ width=30% }]({{ company.website }})
|
||
|
||
```{=latex}
|
||
\end{center}
|
||
```
|
||
---
|
||
|
||
<!-- NOTE: Table of contents section only needs changed if new sections are
|
||
added.
|
||
-->
|
||
|
||
# Contents
|
||
|
||
1. [Introduction](#introduction)
|
||
1. [Airflow Assessment](#airflow-assessment)
|
||
1. [Your Static Measurements](#your-static-measurements)
|
||
1. [Static Pressure Forecast](#static-measurements-forecast)
|
||
1. [Summary](#summary)
|
||
1. [Definitions](#definitions)
|
||
1. [IAQ]
|
||
1. [TESP]
|
||
1. [WC][wc]
|
||
|
||
## Introduction
|
||
|
||
Thank you for having us to your home for a system airflow assessment. I hope that it was beneficial. We learned a lot
|
||
about your system during the brief visit. So, let’s jump in to some of the things discovered.
|
||
|
||
Below is a summary of the system measurements and some recommendations. As part of the service we ran airflow test and
|
||
forecasting.
|
||
|
||
Once you read the report you’ll have 3 options: do nothing, pick and choose upgrades, or do more planning for more
|
||
difficult goals or complex projects. These options are discussed at the end of the report as well as our leanings for
|
||
your home.
|
||
|
||
\newpage
|
||
|
||
## Airflow Assessment
|
||
|
||
While on site, we also measured the total system airflow and static pressure of the system. Static pressure is
|
||
equivalent to the blood pressure of your system and gives us a better understanding of the overall ability for the
|
||
system to provide the proper amount of airflow, as well as how much it may struggle to do so.
|
||
|
||
Static pressure is the amount of resistance that the blower has to work against in order to move air through the system.
|
||
Things that have an effect on the static pressure of the system include, air filters (size and type), duct sizes, amount
|
||
of ducts, length of ducts, duct fittings and transitions, as well as internal system components. Each component of the
|
||
system has a resistance associated with it that the blower has to overcome, by taking some key measurements we are able
|
||
to determine the [TESP] of the system. While there are several static pressures in the system, when we talk about static
|
||
pressure we are generally referring to [TESP].
|
||
|
||
Static pressure ([TESP]) has a range of _low_, _acceptable_, or _high_. While these numbers are specific to the actual
|
||
equipment, most manufacturers follow similar standards. For the sake of simplicity, 0.5" [wc] or under is an
|
||
_acceptable_ target, 0.8" [wc] is generally the max acceptable static pressure (although we like to stay well below this
|
||
if possible), and above 0.8" [wc] is considered _high_ and should be addressed. _Low_ is generally not common and is
|
||
rarely problematic, so it is not focused on much.
|
||
|
||
<!-- NOTE: Force a new page here, for images and sub-section heading to be on same page -->
|
||
|
||
\newpage
|
||
|
||
### Your Static Measurements
|
||
|
||
{height=50%}
|
||
|
||
<!-- WARNING: Summarize the static measurements here -->
|
||
|
||
The above image is a snapshot of the static pressures recorded for your system. This shows that the static pressure of
|
||
your system is very high (1.114" [wc]). The primary culprits for the high static pressure are that the filter is
|
||
undersized for the airflow required and the return duct sizing is small.
|
||
|
||
These measurements were taken in the heating mode because your system does not currently have air conditioning.
|
||
Currently the heating airflow is on the low side for what is required for your system (1200 CFM would be ideal). This
|
||
should be adjusted if possible during the install to get better performance and efficiency out of the system, given that
|
||
some static pressures can be improved during the project.
|
||
|
||
<!-- NOTE: Force a new page here, for images and sub-section heading to be on same page -->
|
||
|
||
\newpage
|
||
|
||
### Static Measurements Forecast
|
||
|
||
{height=50%}
|
||
|
||
<!-- WARNING: Summarize the forecast results below. -->
|
||
|
||
The above image is a snapshot is of a forecast of the static pressures after adding air conditioning. It should be noted
|
||
that these measurements are based solely on the airflow required for cooling mode, not for heating mode (in other words,
|
||
heating mode is going to be higher because the airflow requirement is higher).
|
||
|
||
This shows that with an upgraded filter we can get the static pressure below the 0.8" [wc] max target while in cooling
|
||
mode.
|
||
|
||
\newpage
|
||
|
||
## Summary
|
||
|
||
The purpose of the system airflow assessment is to help find the correct airflow or improvements
|
||
that are required to increase the system longevity and efficiency.
|
||
|
||
<!-- WARNING: Add summary here -->
|
||
|
||
Regards,
|
||
|
||
{width=20%; float=left}
|
||
|
||
\
|
||
\
|
||
|
||
[Here is a link to all the documents][document-folder]
|
||
|
||
> [!NOTE:]
|
||
>
|
||
> Documents are stored on our internal servers and links to your documents expire in approximately 30 days from the
|
||
> creation of your report, for security reasons. We recommend that you download any documents you would like to keep for
|
||
> your records. If you have troubles then we can send the documents via email or extend the expiration date of the
|
||
> provided document links.
|
||
|
||
<!-- prettier-ignore-start -->
|
||
|
||
<!-- NOTE: These are reference links for short form linking in the document.
|
||
This allows all the links to be changed / updated in one place.
|
||
However most do not need updated unless sections are added, besides the
|
||
document links, which are defined / setup in vars.sh.
|
||
-->
|
||
|
||
[IAQ]: #iaq-definition "IAQ"
|
||
[wc]: #wc-definition "wc"
|
||
[TESP]: #tesp-definition "TESP"
|
||
|
||
|
||
<!-- IMPORTANT: Take screen shots of the TrueFlow reports and add to the img
|
||
folder with names / path setup in vars.sh -->
|
||
|
||
<!-- default is img/trueflow.png -->
|
||
[trueflow-image]:
|
||
<!-- default is img/forecast.png -->
|
||
[trueflow-forecast-image]:
|
||
|
||
<!-- IMPORTANT: These links need to be updated. -->
|
||
|
||
[document-folder]:
|
||
<!-- prettier-ignore-end -->
|
||
|
||
```
|
||
|
||
```
|