feat: Working justfile
This commit is contained in:
@@ -1,47 +0,0 @@
|
|||||||
# Definitions
|
|
||||||
|
|
||||||
<!-- NOTE: Keep these at the very bottom, if any new definitions are added then
|
|
||||||
they should also be added as links to the content section near the top. -->
|
|
||||||
|
|
||||||
### CFM50 {#cfm50-definition}
|
|
||||||
|
|
||||||
Is a unit of measurement that is taken when a blower door test is performed on the home. Stands for
|
|
||||||
$C$ubic $F$eet per $M$inute at 50 pascals.
|
|
||||||
|
|
||||||
### IAQ {#iaq-definition}
|
|
||||||
|
|
||||||
Stands for $I$ndoor $A$ir $Q$uality. We spend most of our time indoors, so having good indoor air
|
|
||||||
quality can help reduce illness and potentially improve the quality and longevity of life.
|
|
||||||
|
|
||||||
### LAIR {#lair-definition}
|
|
||||||
|
|
||||||
Stands for $L$eakage $A$ir $I$nfiltration $R$ate, which is a metric that compares the square footage
|
|
||||||
of the home and it's blower door number. This aids in determining if a home is controllable by
|
|
||||||
properly sized HVAC equipment or if [shell] improvements (air sealing and insulation) should be
|
|
||||||
considered.
|
|
||||||
|
|
||||||
### Load Caclulation {#load-calculation-definition}
|
|
||||||
|
|
||||||
A load calculation, also called a Manual-J, calculates the heating and cooling requirements for a
|
|
||||||
home. Each home has a unique heating and cooling load based on the direction it faces, the air
|
|
||||||
leakage, the location, the insulation values, the types and sizes of windows, among other factors.
|
|
||||||
|
|
||||||
### Shell {#shell-definition}
|
|
||||||
|
|
||||||
Shell is a term used to describe the enclosure of the house. It is often used when talking about air
|
|
||||||
leakage and insulation levels.
|
|
||||||
|
|
||||||
### SHR {#shr-definition}
|
|
||||||
|
|
||||||
Stands for $S$ensible $H$eat $R$atio. Sensible heat ratio is the ratio of work required by the air
|
|
||||||
conditioner to remove moisture, as well as maintain the sensible temperature. The higher the number
|
|
||||||
the better.
|
|
||||||
|
|
||||||
### TESP {#tesp-definition}
|
|
||||||
|
|
||||||
Stands for $T$otal $E$xternal $S$tatic $P$ressure, which is a metric used to determine how much
|
|
||||||
resistance the blower motor has to overcome for the airflow requirement of the system.
|
|
||||||
|
|
||||||
### WC {#wc-definition}
|
|
||||||
|
|
||||||
Stands for $W$ater $C$olumn, which is a unit of measurement for pressure.
|
|
||||||
@@ -1,307 +0,0 @@
|
|||||||
---
|
|
||||||
title: "Home Performance Report"
|
|
||||||
author: "Testy McTestface Jr Vault"
|
|
||||||
date: \today{}
|
|
||||||
mainfont: Avenir Next
|
|
||||||
documentclass: article
|
|
||||||
fontsize: 12pt
|
|
||||||
# NOTE: The applegreen is a custom color defined in resources/head.tex
|
|
||||||
linkcolor: applegreen
|
|
||||||
urlcolor: applegreen
|
|
||||||
abstract: |
|
|
||||||
**Prepared For:**
|
|
||||||
|
|
||||||
Testy McTestface Sr
|
|
||||||
|
|
||||||
1234 Seasme Street Vault
|
|
||||||
No Mans Land, Foo 55555
|
|
||||||
|
|
||||||
```{=latex}
|
|
||||||
\begin{center}
|
|
||||||
```
|
|
||||||
<!-- below are just forced line breaks -->
|
|
||||||
\
|
|
||||||
\
|
|
||||||
\
|
|
||||||
|
|
||||||
[{ width=30% }](https://example.com)
|
|
||||||
|
|
||||||
```{=latex}
|
|
||||||
\end{center}
|
|
||||||
```
|
|
||||||
---
|
|
||||||
|
|
||||||
<!-- NOTE: Table of contents section only needs changed if new sections are
|
|
||||||
added.
|
|
||||||
-->
|
|
||||||
|
|
||||||
# Contents
|
|
||||||
|
|
||||||
1. [Introduction](#home-performance-report)
|
|
||||||
1. [Your Goals](#your-goals)
|
|
||||||
1. [Leakage](#how-leaky-is-your-house)
|
|
||||||
1. [Observations](#observations)
|
|
||||||
1. [HVAC](#hvac-observations)
|
|
||||||
1. [Home](#home-observations)
|
|
||||||
1. [Load Calculations](#load-calculations)
|
|
||||||
1. [Your Loads](#your-loads)
|
|
||||||
1. [Airflow Assessment](#airflow-assessment)
|
|
||||||
1. [Your Static Measurements](#your-static-measurements)
|
|
||||||
1. [Static Pressure Forecast](#static-measurements-forecast)
|
|
||||||
1. [Summary](#summary)
|
|
||||||
1. [Definitions](#definitions)
|
|
||||||
1. [CFM50]
|
|
||||||
1. [IAQ]
|
|
||||||
1. [LAIR]
|
|
||||||
1. [Load Calculation][load-calculation]
|
|
||||||
1. [Shell][shell]
|
|
||||||
1. [SHR]
|
|
||||||
1. [TESP]
|
|
||||||
1. [WC][wc]
|
|
||||||
|
|
||||||
# Home Performance Report
|
|
||||||
|
|
||||||
Thank you for having us to your home for a home performance assessment. I hope that it was
|
|
||||||
beneficial. We learned a lot about your home and your goals during the brief visit. So, let’s jump
|
|
||||||
in to some of the things discovered.
|
|
||||||
|
|
||||||
Below is a summary of your goals, house measurements, and our budget discussion as well as my
|
|
||||||
observations and some recommendations. As part of the service we ran load calculations that help
|
|
||||||
determine the right sized HVAC for your home as it stand and with some upgrades. Those are attached
|
|
||||||
as are bids for replacements.
|
|
||||||
|
|
||||||
Once you read the report you’ll have 3 options: do nothing, pick and choose upgrades, or do more
|
|
||||||
planning for more difficult goals or complex projects. These options are discussed at the end of the
|
|
||||||
report as well as our leanings for your home.
|
|
||||||
|
|
||||||
\goalsimage
|
|
||||||
|
|
||||||
## Your goals:
|
|
||||||
|
|
||||||
<!-- NOTE: This should probably be a table in most cases, with a rank.-->
|
|
||||||
|
|
||||||
<!--
|
|
||||||
| Goal | Rank |
|
|
||||||
| ------ | ---- |
|
|
||||||
| A goal | 8 |
|
|
||||||
| B goal | 5 |
|
|
||||||
-->
|
|
||||||
<!-- WARNING: Add goals here -->
|
|
||||||
|
|
||||||
1. Add air conditioning.
|
|
||||||
|
|
||||||
# How Leaky Is Your House
|
|
||||||
|
|
||||||
<!-- NOTE: Several of the variables used in this section are defined in vars.sh
|
|
||||||
Do not change them here, instead update them in the vars.sh file.
|
|
||||||
-->
|
|
||||||
|
|
||||||
One of the main objectives was to perform a blower door test and load calculations for the home. We
|
|
||||||
discovered that the blower door number was 3,000 [CFM50] for the approximately
|
|
||||||
3,000 \squarefoot (1:1 [LAIR]). A leaky home, most often, is an
|
|
||||||
uncomfortable and uncontrollable home.
|
|
||||||
|
|
||||||
> _Air leakage tends to have one of the largest impacts on the load of a home._
|
|
||||||
>
|
|
||||||
> - _Around 1:1 homes begin to be more controllable / comfortable_
|
|
||||||
> - _your home is 3,000:3,000 \squarefoot for a ratio of
|
|
||||||
> 1:1_
|
|
||||||
> - _Leaky homes are very difficult to maintain comfort with HVAC alone._
|
|
||||||
|
|
||||||
# Observations
|
|
||||||
|
|
||||||
The below sections are observations about the current HVAC system and the home.
|
|
||||||
|
|
||||||
## HVAC Observations
|
|
||||||
|
|
||||||
<!-- WARNING: Add HVAC observations here. -->
|
|
||||||
|
|
||||||
1. Current furnace is sized appropriately based on the load of the home.
|
|
||||||
1. Current duct system is not sized adequately for the system.
|
|
||||||
1. Filter is too small for the system.
|
|
||||||
1. Return sizing is not adequate.
|
|
||||||
1. Supply sizing is marginal.
|
|
||||||
1. Current static pressure is already high.
|
|
||||||
1. These problems may become worse when AC is installed.
|
|
||||||
|
|
||||||
## Home Observations
|
|
||||||
|
|
||||||
<!-- WARNING: Add house observations here. -->
|
|
||||||
|
|
||||||
1. The house leakage is high for the size of the home.
|
|
||||||
1. May be hard to control comfort without [shell] improvements.
|
|
||||||
|
|
||||||
# Load Calculations
|
|
||||||
|
|
||||||
Several [load-calculations][load-calculation] were performed on your home to determine the proper
|
|
||||||
equipment sizing for this application. Below is a comparison of the
|
|
||||||
[load-calculations][load-calculation] with the current air leakage and several improved air leakage
|
|
||||||
targets.
|
|
||||||
|
|
||||||
## Your Loads
|
|
||||||
|
|
||||||
<!-- WARNING: Add the project loads here. -->
|
|
||||||
|
|
||||||
| [CFM50] | | Heating Total | Cooling Total | [SHR] | [LAIR] |
|
|
||||||
| -------------------- | ----------- | ------------- | ------------- | -------- | ------------------- |
|
|
||||||
| **3,000** | **Current** | **55,102** | **20,726** | **0.79** | **1:1** |
|
|
||||||
| 2,000 | | 40,320 | 17,279 | 0.85 | 1.5:1 |
|
|
||||||
| 1,350 | | 35,885 | 16,245 | 0.88 | 1:1 |
|
|
||||||
|
|
||||||
> **Note:**
|
|
||||||
>
|
|
||||||
> 1. _The lower the heating and cooling total's the better._
|
|
||||||
> 1. _An undersized air conditioner is better than an oversized one._
|
|
||||||
> 1. _Supplemental dehumidification may be required for [SHR]'s below 0.83._
|
|
||||||
|
|
||||||
The above table shows the relationship between air leakage and the amount of heating and cooling
|
|
||||||
that is required for the home. A tight home is easier to control the comfort levels, offers superior
|
|
||||||
IAQ levels, and lower utility costs.
|
|
||||||
|
|
||||||
<!-- WARNING: Update this summary for the given project -->
|
|
||||||
|
|
||||||
The projected cooling size required for your home is around 2-Tons for the current leakage rate, or
|
|
||||||
1.5-Tons if [shell] improvements were made.
|
|
||||||
|
|
||||||
[Here is a link to your load calculation reports][loads-folder]
|
|
||||||
|
|
||||||
# Airflow Assessment
|
|
||||||
|
|
||||||
While on site, we also measured the total system airflow and static pressure of the system. Static
|
|
||||||
pressure is equivalent to the blood pressure of your system and gives us a better understanding of
|
|
||||||
the overall ability for the system to provide the proper amount of airflow, as well as how much it
|
|
||||||
may struggle to do so.
|
|
||||||
|
|
||||||
Static pressure is the amount of resistance that the blower has to work against in order to move air
|
|
||||||
through the system. Things that have an effect on the static pressure of the system include, air
|
|
||||||
filters (size and type), duct sizes, amount of ducts, length of ducts, duct fittings and
|
|
||||||
transitions, as well as internal system components. Each component of the system has a resistance
|
|
||||||
associated with it that the blower has to overcome, by taking some key measurements we are able to
|
|
||||||
determine the [TESP] of the system. While there are several static pressures in the system, when we
|
|
||||||
talk about static pressure we are generally referring to [TESP].
|
|
||||||
|
|
||||||
Static pressure ([TESP]) has a range of _low_, _acceptable_, or _high_. While these numbers are
|
|
||||||
specific to the actual equipment, most manufacturers follow similar standards. For the sake of
|
|
||||||
simplicity, 0.5" [wc] or under is an _acceptable_ target, 0.8" [wc] is generally the max acceptable
|
|
||||||
static pressure (although we like to stay well below this if possible), and above 0.8" [wc] is
|
|
||||||
considered _high_ and should be addressed. _Low_ is generally not common and is rarely problematic,
|
|
||||||
so it is not focused on much.
|
|
||||||
|
|
||||||
<!-- NOTE: Force a new page here, for images and sub-section heading to be on same page -->
|
|
||||||
|
|
||||||
\newpage
|
|
||||||
|
|
||||||
## Your Static Measurements
|
|
||||||
|
|
||||||
![True Flow Report][trueflow-image]{ height=50% }
|
|
||||||
|
|
||||||
<!-- WARNING: Summarize the static measurements here -->
|
|
||||||
|
|
||||||
The above image is a snapshot of the static pressures recorded for your system. This shows that the
|
|
||||||
static pressure of your system is very high (1.114" [wc]). The primary culprits for the high static
|
|
||||||
pressure are that the filter is undersized for the airflow required and the return duct sizing is
|
|
||||||
small.
|
|
||||||
|
|
||||||
These measurements were taken in the heating mode because your system does not currently have air
|
|
||||||
conditioning. Currently the heating airflow is on the low side for what is required for your system
|
|
||||||
(1200 CFM would be ideal). This should be adjusted if possible during the install to get better
|
|
||||||
performance and efficiency out of the system, given that some static pressures can be improved
|
|
||||||
during the project.
|
|
||||||
|
|
||||||
\
|
|
||||||
\
|
|
||||||
|
|
||||||
[Here is a link to the full airflow report.][trueflow-file]
|
|
||||||
|
|
||||||
<!-- NOTE: Force a new page here, for images and sub-section heading to be on same page -->
|
|
||||||
|
|
||||||
\newpage
|
|
||||||
|
|
||||||
## Static Measurements Forecast
|
|
||||||
|
|
||||||
![True Flow Forecast][trueflow-forecast-image]{ height=50% }
|
|
||||||
|
|
||||||
<!-- WARNING: Summarize the forecast results below. -->
|
|
||||||
|
|
||||||
The above image is a snapshot is of a forecast of the static pressures after adding air
|
|
||||||
conditioning. It should be noted that these measurements are based solely on the airflow required
|
|
||||||
for cooling mode, not for heating mode (in other words, heating mode is going to be higher because
|
|
||||||
the airflow requirement is higher).
|
|
||||||
|
|
||||||
This shows that with an upgraded filter we can get the static pressure below the 0.8" [wc] max
|
|
||||||
target while in cooling mode.
|
|
||||||
|
|
||||||
\
|
|
||||||
\
|
|
||||||
|
|
||||||
[Here is a link to the full forecast report.][trueflow-forecast-file]
|
|
||||||
|
|
||||||
# Summary
|
|
||||||
|
|
||||||
The purpose of the home performance assessment is to help find the overlap between the house needs,
|
|
||||||
the goals, and the budget to see if there's a viable project.
|
|
||||||
|
|
||||||
<!-- WARNING: Add summary here -->
|
|
||||||
|
|
||||||
The house is pretty leaky overall. This is due to the age and construction style of the house. This
|
|
||||||
may lead to comfort problems or trouble maintaining comfort in all areas of the house.
|
|
||||||
|
|
||||||
Based on the [load calculations][load-calculation], the previously quoted systems are too large for
|
|
||||||
the current load, so we need to update the proposals to be for 2-Ton systems. This will help with
|
|
||||||
the fact that the static pressure of the system is already really high. The static pressure for
|
|
||||||
heating will likely still be above the 0.8" [wc] max threshold.
|
|
||||||
|
|
||||||
An upgraded air filter is going to be required to help alleviate the blower motor. Another return
|
|
||||||
may be required in the living space to further drop the static pressure, however this could likely
|
|
||||||
be done in the future if desired. I would estimate that adding another return would be in the
|
|
||||||
**$800-1,200** range.
|
|
||||||
|
|
||||||
While on site it was mentioned that you would like some of the ducts to be sealed that go to the
|
|
||||||
second floor. This is something that is not included in our general proposals. I would estimate this
|
|
||||||
to be an additional **$150-300** and will add options in the updated proposals.
|
|
||||||
|
|
||||||
Since the goal is to add air conditioning, then I would recommend going with a 2-Ton system. If the
|
|
||||||
system does not maintain then you could look into [shell] improvements and air sealing the home.
|
|
||||||
|
|
||||||
Regards,
|
|
||||||
|
|
||||||
\
|
|
||||||
\
|
|
||||||
\
|
|
||||||
|
|
||||||
[Here is a link to all the documents][document-folder]
|
|
||||||
|
|
||||||
<!-- prettier-ignore-start -->
|
|
||||||
|
|
||||||
<!-- NOTE: These are reference links for short form linking in the document.
|
|
||||||
This allows all the links to be changed / updated in one place.
|
|
||||||
However most do not need updated unless sections are added, besides the
|
|
||||||
document links, which are defined / setup in vars.sh.
|
|
||||||
-->
|
|
||||||
|
|
||||||
[CFM50]: #cfm50-definition "CFM50"
|
|
||||||
[IAQ]: #iaq-definition "IAQ"
|
|
||||||
[LAIR]: #lair-definition "LAIR"
|
|
||||||
[load-calculation]: #load-calculation-definition "load calculation"
|
|
||||||
[shell]: #shell-definition "shell"
|
|
||||||
[SHR]: #shr-definition "SHR"
|
|
||||||
[wc]: #wc-definition "wc"
|
|
||||||
[TESP]: #tesp-definition "TESP"
|
|
||||||
|
|
||||||
|
|
||||||
<!-- IMPORTANT: Take screen shots of the TrueFlow reports and add to the img
|
|
||||||
folder with names / path setup in vars.sh -->
|
|
||||||
|
|
||||||
<!-- default is img/trueflow.png -->
|
|
||||||
[trueflow-image]: "img/trueflow.png"
|
|
||||||
|
|
||||||
<!-- default is img/forecast.png -->
|
|
||||||
[trueflow-forecast-image]: "img/forecast.png"
|
|
||||||
|
|
||||||
<!-- NOTE: These links are defined in vars.sh -->
|
|
||||||
|
|
||||||
[loads-folder]: "https://example.com/path/to/loads/folder"
|
|
||||||
[trueflow-file]: "https://example.com/path/to/trueflow/file"
|
|
||||||
[trueflow-forecast-file]: "https://example.com/path/to/trueflow/forecast/file"
|
|
||||||
[document-folder]: "https://example.com/path/to/document/folder"
|
|
||||||
<!-- prettier-ignore-end -->
|
|
||||||
@@ -1,26 +0,0 @@
|
|||||||
% customize the footer
|
|
||||||
\usepackage{fancyhdr}
|
|
||||||
\pagestyle{fancy}
|
|
||||||
% clear all footers
|
|
||||||
\fancyfoot{}
|
|
||||||
% clear all headers
|
|
||||||
\fancyhead{}
|
|
||||||
|
|
||||||
% change font size on footer.
|
|
||||||
\newcommand{\changefont}{
|
|
||||||
\fontsize{8}{10}\selectfont
|
|
||||||
}
|
|
||||||
% NOTE: What is displayed in the footer of each page.
|
|
||||||
\fancyfoot[LE,LO]{
|
|
||||||
\href{ https://example.com }
|
|
||||||
{\changefont\textbf{
|
|
||||||
www.Example.com
|
|
||||||
}}
|
|
||||||
}
|
|
||||||
\fancyfoot[RE,RO]{\textbf{
|
|
||||||
\changefont{
|
|
||||||
Phone: \href{tel:555-555-5555 }{
|
|
||||||
\color{orange}555-555-5555
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}}
|
|
||||||
@@ -1,74 +0,0 @@
|
|||||||
% https://jdhao.github.io/2019/05/30/markdown2pdf_pandoc/#the-top
|
|
||||||
% These were adapted from the above, which was very helpful in getting this
|
|
||||||
% functional.
|
|
||||||
|
|
||||||
% change style of quote, see also https://tex.stackexchange.com/a/436253/114857
|
|
||||||
\usepackage[most]{tcolorbox}
|
|
||||||
|
|
||||||
% change page margins
|
|
||||||
\usepackage[top=2cm, bottom=1.5cm, left=2cm, right=2cm]{geometry}
|
|
||||||
|
|
||||||
% change the line spacing
|
|
||||||
\usepackage{setspace}
|
|
||||||
\setstretch{1.25}
|
|
||||||
|
|
||||||
\usepackage[utf8]{inputenc}
|
|
||||||
|
|
||||||
% NOTE: This needs to stay above hyperref otherwise internal links break.
|
|
||||||
|
|
||||||
% start each section on new page and make section titles orange.
|
|
||||||
\usepackage{titlesec}
|
|
||||||
\titleformat{\section}
|
|
||||||
{\color{orange}\normalfont\Huge\bfseries}
|
|
||||||
\newcommand{\sectionbreak}{\clearpage}
|
|
||||||
|
|
||||||
% custom colors
|
|
||||||
\definecolor{applegreen}{rgb}{0.55,0.71,0.0}
|
|
||||||
|
|
||||||
% Remove figure from images
|
|
||||||
\usepackage[labelformat=empty]{caption}
|
|
||||||
|
|
||||||
\usepackage{fancyvrb,newverbs}
|
|
||||||
|
|
||||||
% see for different color codes https://rgbcolorcode.com/color/E6FFEA
|
|
||||||
\definecolor{linequote}{RGB}{224,215,188}
|
|
||||||
\definecolor{backquote}{RGB}{230,255,234} % background color of quotes
|
|
||||||
\definecolor{bordercolor}{RGB}{221,221,221}
|
|
||||||
|
|
||||||
% change left border: https://tex.stackexchange.com/a/475716/114857
|
|
||||||
% change left margin: https://tex.stackexchange.com/a/457936/114857
|
|
||||||
\newtcolorbox{myquote}[1][]{%
|
|
||||||
enhanced,
|
|
||||||
breakable,
|
|
||||||
size=minimal,
|
|
||||||
left=10pt,
|
|
||||||
top=5pt,
|
|
||||||
bottom=5pt,
|
|
||||||
frame hidden,
|
|
||||||
boxrule=0pt,
|
|
||||||
sharp corners=all,
|
|
||||||
colback=backquote,
|
|
||||||
borderline west={4pt}{0pt}{bordercolor},
|
|
||||||
#1
|
|
||||||
}
|
|
||||||
|
|
||||||
% redefine quote environment to use the myquote environment, see https://tex.stackexchange.com/a/337587/114857
|
|
||||||
\renewenvironment{quote}{\begin{myquote}}{\end{myquote}}
|
|
||||||
|
|
||||||
% remove the abstract title.
|
|
||||||
\usepackage{abstract}
|
|
||||||
\renewcommand{\abstractname}{}
|
|
||||||
\renewcommand{\absnamepos}{empty}
|
|
||||||
|
|
||||||
\def\squarefoot{$ft^{\text{2}}$ }
|
|
||||||
\def\goalsimage{
|
|
||||||
\begin{center}
|
|
||||||
|
|
||||||
\hfill\break
|
|
||||||
\hfill\break
|
|
||||||
|
|
||||||
\includegraphics[width=0.6\linewidth,height=\textheight,keepaspectratio]{img/goals.png}
|
|
||||||
|
|
||||||
\end{center}
|
|
||||||
|
|
||||||
}
|
|
||||||
1
.gitignore
vendored
1
.gitignore
vendored
@@ -2,4 +2,5 @@
|
|||||||
Report.pdf
|
Report.pdf
|
||||||
report.html
|
report.html
|
||||||
outfiles/*
|
outfiles/*
|
||||||
|
.build/*
|
||||||
build/*
|
build/*
|
||||||
|
|||||||
21
Makefile
21
Makefile
@@ -8,7 +8,7 @@ ANSIBLE_DIR = ".ansible"
|
|||||||
.PHONY: pdf
|
.PHONY: pdf
|
||||||
pdf: ansible
|
pdf: ansible
|
||||||
@./scripts/gen.sh "${BUILD_DIR}" "${PWD}/${PDF_TITLE}" \
|
@./scripts/gen.sh "${BUILD_DIR}" "${PWD}/${PDF_TITLE}" \
|
||||||
&& open ${PDF_TITLE} \
|
&& open "${PDF_TITLE}" \
|
||||||
&& osascript ./scripts/notify.scpt
|
&& osascript ./scripts/notify.scpt
|
||||||
|
|
||||||
.PHONY: tex
|
.PHONY: tex
|
||||||
@@ -20,14 +20,6 @@ html: ansible
|
|||||||
@./scripts/gen.sh "${BUILD_DIR}" "${BUILD_DIR}/${HTML_TITLE}" \
|
@./scripts/gen.sh "${BUILD_DIR}" "${BUILD_DIR}/${HTML_TITLE}" \
|
||||||
&& open "${BUILD_DIR}/${HTML_TITLE}"
|
&& open "${BUILD_DIR}/${HTML_TITLE}"
|
||||||
|
|
||||||
.PHONY: install
|
|
||||||
install:
|
|
||||||
@brew install pandoc \
|
|
||||||
mactex-no-gui \
|
|
||||||
imagemagick \
|
|
||||||
gettext \
|
|
||||||
ansible
|
|
||||||
|
|
||||||
.PHONY: ansible
|
.PHONY: ansible
|
||||||
ansible:
|
ansible:
|
||||||
@cd "${ANSIBLE_DIR}" && \
|
@cd "${ANSIBLE_DIR}" && \
|
||||||
@@ -41,7 +33,7 @@ ansible-vault-example:
|
|||||||
--ask-vault-password \
|
--ask-vault-password \
|
||||||
--extra-vars "build_dir=${BUILD_DIR}" \
|
--extra-vars "build_dir=${BUILD_DIR}" \
|
||||||
--extra-vars "@group_vars/vault_example/vars.yaml" \
|
--extra-vars "@group_vars/vault_example/vars.yaml" \
|
||||||
--extra-vars "@group_vars/vault_example/vault.yaml" \
|
--extra-vars "@group_vars/vault_example/vault.yaml"
|
||||||
|
|
||||||
.PHONY: setup
|
.PHONY: setup
|
||||||
setup:
|
setup:
|
||||||
@@ -51,3 +43,12 @@ setup:
|
|||||||
.PHONY: clean
|
.PHONY: clean
|
||||||
clean:
|
clean:
|
||||||
@rm -rf "${BUILD_DIR}"
|
@rm -rf "${BUILD_DIR}"
|
||||||
|
|
||||||
|
.PHONY: install
|
||||||
|
install:
|
||||||
|
@brew install pandoc \
|
||||||
|
mactex-no-gui \
|
||||||
|
imagemagick \
|
||||||
|
gettext \
|
||||||
|
ansible \
|
||||||
|
just
|
||||||
|
|||||||
Reference in New Issue
Block a user