feat: Updates report to add, which rooms leak the most section.
This commit is contained in:
@@ -40,6 +40,7 @@ abstract: |
|
||||
1. [Introduction](#home-performance-report)
|
||||
1. [Your Goals](#your-goals)
|
||||
1. [Leakage](#how-leaky-is-your-house)
|
||||
1. [Which Areas Leak The Most](#which-areas-leak-the-most)
|
||||
1. [Observations](#observations)
|
||||
1. [HVAC](#hvac-observations)
|
||||
1. [Home](#home-observations)
|
||||
@@ -87,12 +88,10 @@ your home.
|
||||
<!-- NOTE: This should probably be a table in most cases, with a rank.-->
|
||||
<!-- WARNING: Add goals here -->
|
||||
|
||||
<!--
|
||||
| Goal | Rank |
|
||||
| :----- | ---: |
|
||||
| A goal | 8 |
|
||||
| B goal | 5 |
|
||||
-->
|
||||
| ---- | ---: |
|
||||
|
||||
\newpage
|
||||
|
||||
# How Leaky Is Your House
|
||||
|
||||
@@ -110,6 +109,27 @@ blower door number was {{ home.cfm50 }} [CFM50] for the approximately {{ home.s
|
||||
> - _your home is {{ home.cfm50 }}:{{ home.square_feet }} \squarefoot for a ratio of {{ home.lair }}_
|
||||
> - _Leaky homes are very difficult to maintain comfort with HVAC alone._
|
||||
|
||||
{width=80%}
|
||||
|
||||
\newpage
|
||||
|
||||
## Which Areas Leak The Most
|
||||
|
||||
While on site, zonal pressure diagnostics were performed to determine which areas leak the most. Below is a table
|
||||
summary of the areas with the most room for improvement.
|
||||
|
||||
<!-- WARNING: Add zonal pressures here. -->
|
||||
|
||||
| **Room** | **Zone Pressure** | **Connection to Outside** |
|
||||
| -------- | ----------------: | ------------------------: |
|
||||
|
||||
> **NOTE:**
|
||||
>
|
||||
> _We use a simplified equation for connection to outside, the actual leakage calculations are beyond the scope of our
|
||||
> consult. The simplified equation is generally a decent representation in most scenarios._
|
||||
|
||||
\newpage
|
||||
|
||||
# Observations
|
||||
|
||||
The below sections are observations about the current HVAC system and the home.
|
||||
@@ -133,6 +153,8 @@ The below sections are observations about the current HVAC system and the home.
|
||||
1. The house leakage is high for the size of the home.
|
||||
1. May be hard to control comfort without [shell] improvements.
|
||||
|
||||
\newpage
|
||||
|
||||
# Load Calculations
|
||||
|
||||
Several [load-calculations][load-calculation] were performed on your home to determine the proper equipment sizing for
|
||||
@@ -165,6 +187,8 @@ improvements were made.
|
||||
|
||||
[Here is a link to your load calculation reports][loads-folder]
|
||||
|
||||
\newpage
|
||||
|
||||
# Airflow Assessment
|
||||
|
||||
While on site, we also measured the total system airflow and static pressure of the system. Static pressure is
|
||||
@@ -230,6 +254,8 @@ mode.
|
||||
|
||||
[Here is a link to the full forecast report.][trueflow-forecast-file]
|
||||
|
||||
\newpage
|
||||
|
||||
# Summary
|
||||
|
||||
The purpose of the home performance assessment is to help find the overlap between the house needs, the goals, and the
|
||||
|
||||